Heat Exchangers For General Applications | Fuel Oil Preheaters |
Heat Exchangers for Special Applications |
Heat Recovery Heat Exchangers | Packaged Heat Transfer Systems | Liquid-Vapor Separators/Boiler
Room Accessories | Storage Tanks |Plate
& Frame Heat Exchangers |Request For Quotation
Download Complete
E-Catalogue
<<< Back To Main Menu
Equipment Selection/Price Quote

 | Heat Exchangers For General Applications Shell & Tube Heat Exchangers are used in the HVAC, chemical, power, and food industries to provide efficient heat transfer between hot and cold fluids. The customer can select the tubing material and the sizes and locations of connections for easy installation and piping, and can choose from four head constructions.
Product Literature: AX - "U-TUBE" STEAM TO LIQUID CONVERTER
ABX - "U-TUBE" LIQUID TO LIQUID HEAT EXCHANGER
ADW - "U-TUBE "STEAM TO WATER INSTANTANEOUS HEATER
AFT - LIQUID TO LIQUID HEAT EXCHANGER WITH STRAIGHT TUBES & FLOATING TUBE SHEET
AFX - HEAT EXCHANGER WITH STRAIGHT TUBES & FIXED TUBESHEET
ATX - "U-TUBE" IMMERSION HEATER
ATB - REPLACEMENT TUBE BUNDLE
AFH-DTB FEEDWATER HEATERS
Equipment Selection/Price Quote | <<< Back To Main Menu
Equipment Selection/Price Quote


 | Fuel Oil Preheaters Alstrom Fuel Oil Heaters serve two major purposes: to make fuel oil "pumpable" and to provide the requested atomization in the burner. Fuel oil has a high viscosity and when stored at the ambient temperature cannot be pumped. The first step is to preheat the fuel oil inside the storage tank, reduce its viscosity , and then dispense it by means of pump suction. "VSF" and "ATL" tank suction heaters are used in underground storage tanks, while "SSF" heaters apply to aboveground tanks. The oil leaving the tank is heated to 110-120°F. Before fuel oil flows to the burner, it receives additional heating. The required fuel oil temperature depends upon the burner design and the grade of fuel oil. Usually, burner manufacturers specify the temperature best suited for their burners. Fuel oil No. 6 is heated to 160°F in horizontal rotary burners, 220°F in steam atomizing burners, and 250°F in mechanical atomizing burners. Alstrom "HST," "ST," "HDT," and "DT" fuel oil heaters are designed for this purpose. For the majority of applications, the electric heater is used for startup. Once the boiler provides sufficient steam pressure or water temperature, the electric heater assumes a standby function. Combination Steam-Electric Fuel Oil Heater "ASE" combines the steam tube bundle and the electrical sheath into one unit, thereby creating a simple, compact, labor-saving package. The properly designed fuel oil preheater provides the necessary fuel oil atomization, resulting in complete combustion and efficient, trouble-free burner maintenance.
Product Literature: HST - BAFFLED "U-TUBE" HEAT EXCHANGER FOR VISCOUS LIQUIDS
ST - MULTIPASS "U-TUBE" FUEL OIL HEATER
HDT - BAFFLED "HERMETIC SAFE GUARD" FUEL OIL PREHEATER
DT - MULTIPASS "SAFE GUARD" FUEL OIL PREHEATER
SSF & VSF - "SMART FLOW" TANK SUCTION FUEL OIL HEATERS
ATL - TUBELESS SUSPENSION SUCTION HEATER
ASE - COMBINATION STEAM-ELECTRIC HEATER
Equipment Selection/Price Quote | |
<<< Back To Main Menu
Equipment Selection/Price Quote |
Heat Exchangers For Special Applications Product Literature:
AFH-DTB -
FEEDWATER HEATER
AHS - INTEGRAL DOUBLE
TUBESHEET HYDRO-SEALED HEAT EXCHANGER
ABX-DTB -
NON-CONTAMINATING HEATER
AVC - LOW PRESSURE
STEAM/VAPOR VENT CONDENSER
BEST - "U-TUBE"
BAFFLED FOR HIGHLY VISCOUS LIQUIDS HEAT EXCHANGER
Equipment Selection/Price Quote | <<< Back To Main Menu
Equipment Selection/Price Quote

| Heat Recovery Heat Exchangers Alstrom Heat Recovery Shell & Tube Heat Exchangers recover and utilize the heat, from liquid and gas streams, which is normally wasted. Generally in the boiler industry, boiler water blowdown is used to maintain the accumulated chemical concentration levels recommended by the boiler manufacturer. The wasted heat is transferred to the make up water in our ABD heat exchanger. Depending on steam consumption, the ratio of the blowdown water to the make up water volume flow rate is 0.02-0.20. The best heat transfer occurs when the blowdown water passes through the multiple passes of tubing and the make up water flows through the shell Alstrom heat exchangers ATC provides the countercurrent heat transfer for the crossing temperatures common in heat recovery installations. Depending on the temperatures and flow rates of the hot and cold streams, multiple shell heat exchanger AMS may be required.
Product Literature: ABD MULTIPASS BLOWDOWN HEAT EXCHANGER
ATC TRUE COUNTERCURRENT FLOW HEAT EXCHANGER
AMS MULTIPLE SHELL COUNTERCURRENT FLOW HEAT EXCHANGER
Equipment Selection/Price Quote | <<< Back To Main Menu
Equipment Selection/Price Quote


| Packaged Heat Transfer Systems Customarily, the control devices, pumps, and other accessories that make up heat exchanger packages are installed at the job site. This increases the man-hours required for on-site field work and limits assembly quality to the installer's level of qualification. Alstrom Packaged Units, which include our high quality heat exchangers, are conveniently packaged and only require connection to the service. All components are sized, mounted, and piped prior to shipment, with the exception of certain items (e.g., thermometers and pressure gauges) which can be damaged during shipping. Each package is designed, manufactured, and hydrostatically tested in our facilities. All components are supplied by the most reliable and well-respected manufacturers in the United States. Alstrom pre-engineered packaged units save on installation time and guarantee qualified factory assembly. While manufactured from a similar design concept, each unit is customized according to the client's specific needs and performance requirements. In the future, we intend to add more packages to our production line, and we appreciate your suggestions regarding these and other packages.
Product Literature: ALSTAR-L - BLOWDOWN HEAT RECOVERY PACKAGE FOR LOW PRESSURE STEAM GENERATOR
ALSTAR - BLOWDOWN HEAT RECOVERY PACKAGE
ALSTAR PLUS - BLOWDOWN HEAT RECOVERY PACKAGE WITH CONDENSATE RECOVERY
STEAM SAVER
ASTEG - UNFIRED STEAM GENERATOR
ECOPAC - INSTANTANEOUS WATER HEATER
Equipment Selection/Price Quote |
<<< Back To Main Menu
Equipment Selection/Price Quote
 |
Liquid-Vapor Separators/Boiler
Room Accessories
Product Literature:
INLINE ENTRAINMENT SEPARATORS "ALSEP"
TWO PHASE FLOW SEPARATORS "ALMUS"
CENTRIFUGAL VAPOR-LIQUID SEPARATORS "ALCENT"
BLOWDOWN SEPARATORS
"ABDS"
EXHAUST HEADS
"CYCLONE"
Equipment Selection/Price Quote |
<<< Back To Main Menu
Equipment Selection/Price Quote


|
Storage Tanks
Product Literature:
ASTOR - HOT WATER SUPPLY STORAGE TANK
HOT WATER GENERATOR "ASH-H"
HOT WATER GENERATOR "ASH-V
HOT WATER GENERATOR "ASH-HF"
HOT WATER GENERATOR "ASH-VF"
Equipment Selection/Price Quote | | | |
Download Complete E-Catalogue
Heat Exchangers For General Applications | Fuel Oil Preheaters |
Heat Exchangers for Special Applications |
Heat Recovery Heat Exchangers | Packaged Heat Transfer Systems | Liquid-Vapor Separators/Boiler
Room Accessories | Storage Tanks |Plate