STAINLESS STEEL TUBING VS COPPER TUBING IN SHELL & TUBE HEAT EXCHANGERS

New study of Brookhaven National Laboratory, contributed by NORA (The National Oil Heat Research Alliance) supports our long policy of using 316 Stainless Steel tubing for    manufacturing shell& tube heat exchangers.

“According to NORA study, one of the keys to maximize fuel performance is characterizing oil sludge and determining its possible contribution… Deposits found in copper tubing consisted of oxidized fuel. The clogging of copper fuel lines was one of the problems discovered, as the study found solid black particles that adhered to tube surface. Cooper has also been known to accelerate fuel-degradation process, forming particulates. On the other hand, far fewer solid and gum were produced by fuel when exposed to steel and stainless steel. The reports recommend using steel piping materials wherever it is feasible.”

This phenomenon is taken in account for heat transfer calculations. TEMA (Standards of the Tubular Exchanger Manufacturers Association) determines Chemical Reaction Corrosion

 “… Coking, the hard crust deposit of hydrocarbons formed on heat transfer surfaces, is a common form of this type of fouling.”   We can not recommend any means to remove this deposit from the tubing.

The high thermal conductivity of copper can not compensate poor thermal conductivity of  organic solid black particles resulting in decrease of heat transfer.  

Table 1 demonstrates the effect of fouling on thermal resistance of copper and stainless steel tubes with wall thickness of 0.049”.

 Copper Stainless Steel
k- Btu/(hr ft deg. F)225.008.4
t/k - (hr sq. ft deg. F)/Btu0.00001810.0004861
Fouling  0.0050.005   (per TEMA)
Total0.00501810.0054861
Per Cent100%109.3%
 

 

 

 

Where:  t/k-Thermal Resistance of the tubes, t-wall thickness, k- coefficient of thermal conductivity.

Regretfully, TEMA Recommended Good Practice values of Fouling Resistances for Industrial Liquids do not take in consideration effect of tube material.

If the actual Fouling Resistance of # 6 Fuel Oil in the heater made from stainless steel tubing equals to 0.0025, then:

Fouling0.0050.0025
Total0.00501810.0029861
Per Cent100%    40%
 

 

 

These calculations show that thermal resistance of stainless steel tubes in the fuel oil preheater will be less then thermal resistance of copper tubes, accumulated coked hard crust deposit of hydrocarbons. The thermal resistance of the tubing is only a part of total resistance of heat transfer, and the effect of fouling and tubing material can be accurately calculated in the process of the thermal design of a heat exchanger.

The coking of hydrocarbons accelerated at elevated temperature of heating tubes. The evaporation of light hydrocarbon residue fractions definitely accelerates coking.

As a good practice, The Alstrom Corporation recommends to maintain the temperature of heating media about 120 deg. F above the outgoing temperature of the #6 heating oil or less.

For instance, 

#6 Fuel Oil Outgoing Temperature, deg.F

Recommended Temperature of Heating Media, deg.F

Maximal Steam Pressure, psig

12024010
15027030
18030050
220340100
250370150
 

 

 

 

The excessive steam pressure can be used to size temperature regulator.

These recommendations are valid for asphalt and other highly viscous liquids. For instance, heating syrups may result in carmelization of the fluid.

Similar, but in less degree, phenomena occurs in shell & tube heat exchangers for water heating. Indeed, copper tubes are oxidized, resulting in fast accumulation of solid deposits.

Copper has poor mechanical properties, particularly on elevated temperatures common in heat transfer. 

Tube-to-tubesheet joint of copper tubes with other materials commonly made by tube expansion. ASME Boiler & Pressure Vessel Code estimates efficiency if expanded joint 60-65%.  Stainless steel tubes can be not only expanded but also seal welded to the tubesheet, resulting in 100% joint efficiency.  In this case, according to the Standard for Power Plant Heat Exchangers of Heat Exchange Institute, the metal temperature of welded joint can reach the maximum value permitted by ASME Code.

After introducing 316 Stainless Steel tubes as a standard material of fabrication shell & tube heat exchangers and using expansion-welding technology The Alstrom Corporation was never reported about tube damage or leak in the tube-to-tubesheet joint.


PDF Printable Version

 Download Latest Acrobat Reader

 
 
 
 